G12 - M8 - S8 infrarood stralers Torvic Agro Slide
hoofd 2200x600
voileres
Torvic Agro, Your partner in livestock environment
Heating solutions
Product specifications
Torvic Agro

M-BROODER

The Gasolec M-series stainless steel heaters are engineered for efficiency, durability, and ease of use, making them a trusted choice for swine housing. These heaters provide several key advantages:

  • Lower Gas Consumption: Designed to minimize waste and reduce the need for venting excess heat.
  • Durable Design: Lightweight, resistant to damage, and built to withstand high-pressure cleaning for long-term use.
  • Adjustable Heating Capacity: The M8 model offers an adjustable range from 100% to 12%, ensuring optimal gas usage when less heat is required.
  • Biosecurity: Stainless steel construction facilitates easy cleaning with high-pressure washing and chemicals, supporting better hygiene and biosecurity.
  • Thermo-Unit Control: No electricity or computer required. The built-in thermo-unit automatically adjusts heat output between maximum and minimum based on the desired room temperature (20°C to 36°C).

Applications
The M-Heater series is perfect for:

  • Farrowing Crates/Houses
  • Nursery/Weaner Housing
  • Wean-to-Finish Housing
  • Quarantine Facilities

For more information about the M-Heater series, please scroll down.

Torvic Agro

  • Models

    Models

    Model

    BTU/HR input

    Capacity

    Mounting Height

    Gas Consumption

    mBar

    M2

    3.400

    1 kW

    50 - 70 cm

    • Propane – 72 gr/h
    • Natural Gas High – 0.09m3/h
    • Natural Gas Low -0.108m3/h
    • 20-310
    • 20-50, 20-300
    • 20-50, 20-300

    M3

    5.118

    1.5 kW

    60 - 80 cm

    • Propane – 108 gr/h
    • Natural Gas High -0.135m3/h
    • Natural Gas Low -0.162m3/h
    • 20-310
    • 20-50, 20-300
    • 20-50, 20-300

    M5

    10.236

    3 kW

    90 - 120 cm

    • Propane – 216 gr/h
    • Natural Gas High -0.270m3/h
    • Natural Gas Low -0.324m3/h
    • 20-1400, 20-310
    • 20-50, 20-300
    • 20-50, 20-300

    M8

    17.060

    5 kW

    90 - 150 cm

    • Propane – 360 gr/h
    • Natural Gas High -0.450m3/h
    • Natural Gas Low -0.540m3/h
    • 20-1400, 20-310
    • 20-50, 20-300
    • 20-50, 20-300

    For other gas types and gas pressures contact your dealer or contact Torvic Agro B.V.

  • Advantages

    Advantages

    • Higher Efficiency: More efficient than direct or indirect hot air heaters.
    • Wide Adjustable Heating Capacity: Adjustable from 12% to 100% with propane.
    • Comfort Zones: Allows animals to select their preferred temperature.
    • Durable Stainless Steel Construction: Lightweight and resistant to damage.
    • No Breakable Components: Designed without fragile ceramics.
    • Easy Cleaning: Withstands high-pressure washing.
    • Low Maintenance: Built for reliability and ease of care.
    • Adjustable Capacity: Heating capacity controlled via gas pressure.
    • Simple, Efficient Design: Effective performance without complexity.
    • Standard SS Filter: Comes with a stainless steel filter.
    • Optional HD Filter: Heavy-duty filter available for enhanced dust protection.
    • Safety Features: Standard thermo-electromagnetic safety device; optional version includes integrated clixon.
  • Coverage

    Coverage

    Model

    Coverage*

    M2

    Broilers

    Up to 180

    M2

    Turkeys

    Up to 40

    M2

    Pigs / Weaners

    Up to 10

    M3

    Broilers

    Up to 300

    M3

    Turkeys

    Up to 60

    M3

    Pigs / Weaners

    Up to 15

    M5

    Broilers

    Up to 700

    M5

    Turkeys

    Up to 200

    M5

    Pigs / Weaners

    Up to 40

    M8

    Broilers

    Up to 1200

    M8

    Turkeys

    Up to 350

    M8

    Pigs / Weaners

    Up to 70

    *The numbers are indications only. All depending on the local (weather) conditions and housing style.

  • Dust filter options

    Dust filter options

    Dust and other materials being drawn into the heater can cause incomplete combustion, which may release toxic substances. To prevent this, every heater is equiped with a dust filter. There are two types of filters available:

    SS Filter (standard) - PU320
    The SS (Stainless Steel) filter comes standard with every S-series heater. Its design ensures durability and ease of maintenance. The filter can be quickly cleaned by hand during the production cycle and thoroughly cleaned with compressed air or water after each cycle.

    HD Filter (optional) - PU321
    The HD (Heavy Duty) filter is a completely different type of filter. Made from durable cloth material, it prevents 99% of dust particles from entering the S-heater—significantly more than the SS filter can achieve. Thanks to its folded design, the overall filter area is much larger compared to the SS filter, reducing the frequency of cleaning required. The HD filter can be easily cleaned by hand during the production cycle and thoroughly cleaned with water or compressed air after each cycle.

  • Shipping info

    Shipping info

    Model

    kW input

    Net Weight

    20 feet container40 feet container40 feet HQ container

    M2

    1 kW

    1.05kg

    xxx

    M3

    1.5 kW

    1.05kg

    xxx

    M5

    3 kW

    1.55kg

    2,0004,1004,800

    M8

    5 kW

    1.57kg

    2,0004,1004,800
  • Product documents

    Product documents

Other Heating solutions

As close to nature as heating can be

Direct contact

Direct contact

Vul uw contactgegevens in
Stay informed: Receive our newsletter now

Stay up to date with the latest news? Sign up here and receive our newsletter!

Sign Up

Stay informed