How to Replace the Thermocouple on a Gasolec S-Series Brooder

Learn how to safely replace the thermocouple on a Gasolec S8 infrared brooder. The same procedure also applies to the Gasolec S2 and S4 brooders. The thermocouple is an essential part of the flame-failure safety system.

In this step-by-step tutorial, we show you how to:

• Remove the old thermocouple

• Install the replacement thermocouple correctly

• Prevent damage caused by overtightening

• Prepare the brooder for safe operation

 

Tools required:

• 8 mm open-ended wrench

• Approved Gasolec replacement thermocouple (250mm)

 

 

 

 